• Home
  • Otology
  • Rhinology
  • Laryngology
  • Recent advances
  • Multiple choice questions
  • Surgical videos
  • Interesting case reports
  • E books
  • UG Question papers (MGR University)
  • PG Question papers (MGR University)
  • OSCE Notes
  • Slide Presentations
  • E Tutorials
  • Atlas
  • Short topics
  • Mirror
  • Scribd
  • Contact

Welcome

 



<meta name="GENERATOR" content="OpenOffice.org 3.2 (Linux)" /> <style type="text/css"> <!-- @page { margin: 2cm } P { margin-bottom: 0.21cm } --> </style> <p style="margin-bottom: 0cm;" align="center"><small><font size="6"><small>Role of optical diagnostics in the early detection of oral mucosal cancers</small></font></small></p> <p style="margin-bottom: 0cm;" align="center"><br /> </p> <p style="margin-bottom: 0cm;" align="center"><small><font size="6"><small><small><small>Dr T Balasubramanian</small></small></small></font></small></p> <p style="margin-bottom: 0cm;" align="center"><br /> </p> <p style="margin-bottom: 0cm; text-align: left;"><br /> </p> <p style="margin-bottom: 0cm; text-align: left;"><br /> </p> <p style="margin-bottom: 0cm; text-align: left;"> <meta http-equiv="CONTENT-TYPE" content="text/html; charset=utf-8" /><title /><meta name="GENERATOR" content="OpenOffice.org 3.2 (Linux)" /> <style type="text/css"> <!-- @page { margin: 2cm } P { margin-bottom: 0.21cm } --> </style> <p style="margin-bottom: 0cm;" align="left"><font size="3">Introduction:</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">When light passes through tissue it undergoes various modifications depending on tissue biological properties. Analysis of this light will provide vital insights into the physiological condtion of the tissue at a molecular level. This property of light is made use of in early diagnosis of superficial mucosal malignant lesions. Studies have demonstrated that many of the biological events leading on to development of malignancies also alter the optical properties of the tissue causing them to produce characteristic optical signatures which can be easily recorded. Various types of light based detection systems have been developed to identify these optical signatures.</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">Advantages of optical diagnostic system:</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <ol><li><p style="margin-bottom: 0cm;" align="left"><font size="3">It is non invasive</font></p> </li><li><p style="margin-bottom: 0cm;" align="left"><font size="3">It can precisely identify suspicious lesions for specific biopsy procedures to be performed</font></p> </li><li><p style="margin-bottom: 0cm;" align="left"><font size="3">It has the potential to provide real time tissue assessment</font></p> </li></ol> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">Types of optical diagnostic system:</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <ol><li><p style="margin-bottom: 0cm;" align="left"><font size="3">Spectoscopy</font></p> </li><li><p style="margin-bottom: 0cm;" align="left"><font size="3">Fluorescence spectroscopy</font></p> </li><li><p style="margin-bottom: 0cm;" align="left"><font size="3">Elastic scattering spectroscopy</font></p> </li><li><p style="margin-bottom: 0cm;" align="left"><font size="3">Raman spectroscopy</font></p> </li><li><p style="margin-bottom: 0cm;" align="left"><font size="3">Fluorescence imaging</font></p> </li><li><p style="margin-bottom: 0cm;" align="left"><font size="3">Optical coherence tomography</font></p> </li><li><p style="margin-bottom: 0cm;" align="left"><font size="3">Narrow band imaging</font></p> </li><li><p style="margin-bottom: 0cm;" align="left"><font size="3">Multimodal optical imaging</font></p> </li></ol> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">Spectroscopy:</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">This method is used to analyse the changes undergone by light passing through tissue. The tissue while undergoing changes from normal to neoplasia undergoes complex molecular transformation. These transformations modifies the manner in which light is absorbed / reflected from the tissue. While performing spectroscopic analysis of tissue, the light of specific wave length is delivered to the tissue via an optical probe. The spectral pattern produced by the light reacting with the tissue is analysed for light – tissue interactions.</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">Fluorescence spectroscopy:</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">This study is based on biological emission of fluorescent light when the tissue studied is exposed to ultraviolet / short wavelength visible light. Light is composed of energy packages known as photons. Tissues on being exposed to light may cause absorption / reflection / scattering of photons. Tissues are known to contain light reactive biomolecules known as fluoropores. These fluoropores absorb energy from light and emit fluorescent light of lower energy and longer wave length. Study of this emitted light from tissue will provide valuable insight of biological status of the tissue. </font> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">The concentration and distribution of fluorophores vary as the tissue undergoes malignant transformation. This becomes clearly evident in the spectroscopic pattern produced.</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">Elastic scattering spectroscopy:</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">This is also known as diffuse reflectance spectroscopy. Here white light (400 – 700 micrometer) is used to illuminate the tissue under study. Photons from this visible light gets reflected from the tissue without a change in wavelength / energy. The reflected light can be measured to look for changes. This reflected light is known as scattering. Tissues with malignant potential show different scattering pattern.</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">Raman spectroscopy:</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">This method can be used to provide detailed information about molecular composition of tissue. Raman spectra is generated by inelastic scattering of light which is highly molecule specific. The light source used is usually in the infra red spectrum. Infrared light on striking the tissue undergoes wavelength shift which is caused by energy transfer between incident photon and tissue molecules. This subtle shift in wavelength of light can be spectroscopically analysed.</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">Fluorescence imaging:</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">These system classically use the principle of spectroscopy to capture fluorescence emission from a larger surface area of tissue. The image is usually captured in real time using a camera. The tissue is illuminated with light source generating light in the uv range. These systems are capable of capturing images from large tissue areas.</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">Optical coherance tomography:</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">This imaging technique provides high resolution cross sectional images of the tissue studied. The technology involved is most similar to B scan (Ultrasound). This technique detects back scattered light waves after the tissue is probed with low power infrared light source. The optical probe used is about 2 mm in diameter. The tissue in study can be scanned in transverse / linear / radial fashion.</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">Narrow band imaging:</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">This technique helps in visualizing microvasculature of surface mucosa. Optical interference filters in red / green / blue range are used to limit the penetration of tissue by light. Hemoglobin is known to absorb blue light. Just by studying tissue absorption of blue spectrum of light an indirect assessment of vascularity of the tissue studied can be made. Since malignant transformation of tissue is assocaited with formation of new blood vessels this imaging modality shows clearly the malignant transformation of tissue.</font></p> <p style="margin-bottom: 0cm;" align="left"><br /> </p> <p style="margin-bottom: 0cm;" align="left"><font size="3">Multimodal optical imaging:</font></p> <p style="margin-bottom: 0cm;" align="left"><font size="3">These devices make use of 2 / more technologies descussed above. These devices can also be used to assess tissue in real time. Since it involves more than one spectroscopic imaging technique the results are fairly accurate.</font></p> </p>  </p> <p> </p> <p> </p> <p> </p> <p> </p> <p> </p> <p> </p> <p> </p> <p> </p> <p> </p> <p> </p> <p> </p><form action="/cgi-sys/entropysearch.cgi" target="searchwindow">Search Query <input name="query" value="" type="text" /> <input name="user" value="drtbalu1" type="hidden" /><input name="basehref" value="http://drtbalu.com" type="hidden" /> <input name="template" value="default" type="hidden" /><input value="Search" type="submit" /> </form>   </div> </div> <div class="clear"> </div> </div> <div id="footer"> <div id="copyright"> <span>© Copyright drtbalu's otolaryngology online, 2005.<br /> All rights reserved.</span> </div> <div><a href="blip.html"><img src="images/blip.png" height="74" width="112" /></a> <a href="http://www.youtube.com/user/drtbaluent"><img src="images/youtube.jpg" height="74" width="112" /></a> <a href="http://drtbalu.co.in/news/"><img src="images/news.jpg" height="74" width="112" /></a> <a href="http://www.rhinology.drtbalu.com/index.php?option=com_kunena&view=entrypage&defaultmenu=57&Itemid=55"><img src="images/forum.jpeg" height="74" width="112" /></a></div> </div> <div id="footerend"> <div id="payment"> </div> </div></div></div> </body></html>